Volume 9 Issue 2
Mar.  2018
Turn off MathJax
Article Contents

doi: 10.3969/j.issn.1674-7445.2018.02.013
  • Received Date: 2017-11-05
    Available Online: 2021-01-19
  • Publish Date: 2018-03-15
  • loading
  • [1]
    张驌, 付生军, 杨立, 等.Lifeport在肾移植中的应用研究进展[J].器官移植, 2015, 6(5): 298-302. DOI: 10.3969/j.issn.1674-7445.2015.05.004.

    ZHANG S, FU SJ, YANG L, et al. Research progress of Lifeport application in renal transplantation[J]. Organ Transplant, 2015, 6(5): 298-302. DOI: 10.3969/j.issn.1674-7445.2015.05.004.
    [2]
    TRECKMANN J, MOERS C, SMITS JM, et al. Machine perfusion versus cold storage for preservation of kidneys from expanded criteria donors after brain death[J]. Transpl Int, 2011, 24(6): 548-554. DOI: 10.1111/j.1432-2277.2011.01232.x.
    [3]
    JIAO B, LIU S, LIU H, et al. Hypothermic machine perfusion reduces delayed graft function and improves one-year graft survival of kidneys from expanded criteria donors: a meta-analysis[J]. PLoS One, 2013, 8(12): e81826. DOI: 10.1371/journal.pone.0081826.
    [4]
    YAO L, ZHOU H, WANG Y, et al. Hypothermic machine perfusion in DCD kidney transplantation: a single center experience[J]. Urol Int, 2016, 96(2): 148-151. DOI: 10.1159/000431025.
    [5]
    ZHOU J, LI YS, CHIEN S. Shear stress-initiated signaling and its regulation of endothelial function[J]. Arterioscler Thromb Vasc Biol, 2014, 34(10): 2191-2198. DOI: 10.1161/ATVBAHA.114.303422.
    [6]
    BAEYENS N, BANDYOPADHYAY C, COON BG, et al. Endothelial fluid shear stress sensing in vascular health and disease[J]. J Clin Invest, 2016, 126(3): 821-828. DOI: 10.1172/JCI83083.
    [7]
    YOUNG A, WU W, SUN W, et al. Flow activation of AMP-activated protein kinase in vascular endothelium leads to Krüppel-like factor 2 expression[J]. Arterioscler Thromb Vasc Biol, 2009, 29(11): 1902-1908. DOI: 10.1161/ATVBAHA.109.193540.
    [8]
    CHATTERJEE S, FISHER AB. Mechanotransduction: forces, sensors, and redox signaling[J]. Antioxid Redox Signal, 2014, 20(6): 868-871. DOI: 10.1089/ars.2013.5753.
    [9]
    CHATTERJEE S, NIEMAN GF, CHRISTIE JD, et al. Shear stress-related mechanosignaling with lung ischemia: lessons from basic research can inform lung transplantation[J]. Am J Physiol Lung Cell Mol Physiol, 2014, 307(9): L668-L680. DOI: 10.1152/ajplung.00198.2014.
    [10]
    CHATTERJEE S, FISHER AB. Mechanotransduction in the endothelium: role of membrane proteins and reactive oxygen species in sensing, transduction, and transmission of the signal with altered blood flow[J]. Antioxid Redox Signal, 2014, 20(6): 899-913. DOI: 10.1089/ars.2013.5624.
    [11]
    丁汉东, 廖贵益.移植肾缺血-再灌注损伤的发生机制及其保护研究进展[J].器官移植, 2016, 7(2): 155-158. DOI: 10.3969/j.issn.1674-7445.2016.02.015.

    DING HD, LIAO GY. Research progress on mechanism and its protection on ischemia-reperfusion injury of transplant kidney[J]. Organ Transplant, 2016, 7(2): 155-158. DOI: 10.3969/j.issn.1674-7445.2016.02.015.
    [12]
    WATSON CJ, WELLS AC, ROBERTS RJ, et al. Cold machine perfusion versus static cold storage of kidneys donated after cardiac death: a UK multicenter randomized controlled trial[J]. Am J Transplant, 2010, 10(9): 1991-1999. DOI: 10.1111/j.1600-6143.2010.03165.x.
    [13]
    GILL J, DONG J, ENG M, et al. Pulsatile perfusion reduces the risk of delayed graft function in deceased donor kidney transplants, irrespective of donor type and cold ischemic time[J]. Transplantation, 2014, 97(6): 668-674. DOI: 10.1097/01.TP.0000438637.29214.10.
    [14]
    SALVADORI M, ROSSO G, BERTONI E. Update on ischemia-reperfusion injury in kidney transplantation: pathogenesis and treatment[J]. World J Transplant, 2015, 5(2): 52-67. DOI: 10.5500/wjt.v5.i2.52.
    [15]
    MOERS C, PIRENNE J, PAUL A, et al. Machine perfusion or cold storage in deceased-donor kidney transplantation[J]. N Engl J Med, 2012, 366(8): 770-771. DOI: 10.1056/NEJMc1111038.
    [16]
    程颖.机械灌注在肝移植中的应用[J].器官移植, 2016, 7(5): 390-393. DOI: 10.3969/j.issn.1674-7445.2016.05.012.

    CHENG Y. Application of mechanical perfusion in liver transplantation[J]. Organ Transplant, 2016, 7(5): 390-393. DOI: 10.3969/j.issn.1674-7445.2016.05.012.
    [17]
    项和立, 薛武军, 田普训, 等.机械灌注在公民逝世后器官捐献肾移植中的应用[J].中华器官移植杂志, 2015, 36(6): 330-334. DOI: 10.3760/cma.j.issn.0254-1785.2015.06.002.

    XIANG HL, XUE WJ, TIAN PX, et al. Clinical application of mechanical perfusion in donation after citizen's death donor renal transplantation[J]. Chin J Organ Transplant, 2015, 36(6): 330-334. DOI: 10.3760/cma.j.issn.0254-1785.2015.06.002.
    [18]
    项和立, 薛武军, 田普训, 等.公民逝世后器官捐献供者的评估与维护[J].中华器官移植杂志, 2014, 35(7): 392-395. DOI: 10.3760/cma.j.issn.0254-1785.2014.07.003.

    XIANG HL, XUE WJ, TIAN PX, et al. Donor evaluation and maintenance of donation after citizen's death[J]. Chin J Organ Transplant, 2014, 35(7): 392-395. DOI: 10.3760/cma.j.issn.0254-1785.2014.07.003.
    [19]
    ZHONG Z, HU Q, FU Z, et al. Increased expression of aldehyde dehydrogenase 2 reduces renal cell apoptosis during ischemia/reperfusion injury after hypothermic machine perfusion[J]. Artif Organs, 2016, 40(6): 596-603. DOI: 10.1111/aor.12607.
    [20]
    LA MANNA G, CONTE D, CAPPUCCILLI ML, et al. An in vivo autotransplant model of renal preservation: cold storage versus machine perfusion in the prevention of ischemia/reperfusion injury[J]. Artif Organs, 2009, 33(7): 565-570. DOI: 10.1111/j.1525-1594.2009.00743.x.
    [21]
    HOSGOOD SA, YANG B, BAGUL A, et al. A comparison of hypothermic machine perfusion versus static cold storage in an experimental model of renal ischemia reperfusion injury[J]. Transplantation, 2010, 89(7): 830-837. DOI: 10.1097/TP.0b013e3181cfa1d2.
    [22]
    VAZIRI N, THUILLIER R, FAVREAU FD, et al. Analysis of machine perfusion benefits in kidney grafts: a preclinical study[J]. J Transl Med, 2011(9): 15. DOI: 10.1186/1479-5876-9-15.
    [23]
    GRACIA-SANCHO J, VILLARREAL G JR, ZHANG Y, et al. Flow cessation triggers endothelial dysfunction during organ cold storage conditions: strategies for pharmacologic intervention[J]. Transplantation, 2010, 90(2): 142-149. DOI: 10.1097/TP.0b013e3181e228db.
    [24]
    CHATAURET N, COUDROY R, DELPECH PO, et al. Mechanistic analysis of nonoxygenated hypothermic machine perfusion's protection on warm ischemic kidney uncovers greater eNOS phosphorylation and vasodilation[J]. Am J Transplant, 2014, 14(11):2500-2514. DOI: 10.1111/ajt.12904.
    [25]
    薛帅, 曾承, 方泽鸿, 等.AMPK减轻肝脏缺血再灌注损伤作用的研究进展[J].中华器官移植杂志, 2017, 38(5): 312-315. DOI: 10.3760/cma.j.issn.0254-1785.2017.05.013.

    XUE S, ZENG C, FANG ZH, et al. Research progress of AMPK reduce the liver ischemia-reperfusion injury[J]. Chin J Organ Transplant, 2017, 38(5): 312-315. DOI: 10.3760/cma.j.issn.0254-1785.2017.05.013.
    [26]
    VESTWEBER D. How leukocytes cross the vascular endothelium[J]. Nat Rev Immunol, 2015, 15(11): 692-704. DOI: 10.1038/nri3908.
    [27]
    SENBANERJEE S, LIN Z, ATKINS GB, et al. KLF2 is a novel transcriptional regulator of endothelial proinflammatory activation[J]. J Exp Med, 2004, 199(10): 1305-1315. doi: 10.1084/jem.20031132
    [28]
    NOVODVORSKY P, CHICO TJ. The role of the transcription factor KLF2 in vascular development and disease[J]. Prog Mol Biol Transl Sci, 2014(124): 155-188. DOI: 10.1016/B978-0-12-386930-2.00007-0.
    [29]
    SLATER SC, RAMNATH RD, UTTRIDGE K, et al. Chronic exposure to laminar shear stress induces Kruppel-like factor 2 in glomerular endothelial cells and modulates interactions with co-cultured podocytes[J]. Int J Biochem Cell Biol, 2012, 44(9): 1482-1490. DOI: 10.1016/j.biocel.2012.05.020.
    [30]
    TOZZI M, FRANCHIN M, SOLDINI G, et al. Impact of static cold storage VS hypothermic machine preservation on ischemic kidney graft: inflammatory cytokines and adhesion molecules as markers of ischemia/reperfusion tissue damage. our preliminary results[J]. Int J Surg, 2013, 11 (Suppl 1): S110-S114. DOI: 10.1016/S1743-9191(13)60029-1.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (107) PDF downloads(10) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return