留言板

尊敬的读者、作者、审稿人, 关于本刊的投稿、审稿、编辑和出版的任何问题, 您可以本页添加留言。我们将尽快给您答复。谢谢您的支持!

姓名
邮箱
手机号码
标题
留言内容
验证码

剪切波弹性成像在肾移植中的应用进展

鹿晋铭, 欧志宇, 苗芸. 剪切波弹性成像在肾移植中的应用进展[J]. 器官移植, 2022, 13(2): 266-270. doi: 10.3969/j.issn.1674-7445.2022.02.017
引用本文: 鹿晋铭, 欧志宇, 苗芸. 剪切波弹性成像在肾移植中的应用进展[J]. 器官移植, 2022, 13(2): 266-270. doi: 10.3969/j.issn.1674-7445.2022.02.017
Lu Jinming, Ou Zhiyu, Miao Yun. Research progress on application of shear wave elastography in kidney transplantation[J]. ORGAN TRANSPLANTATION, 2022, 13(2): 266-270. doi: 10.3969/j.issn.1674-7445.2022.02.017
Citation: Lu Jinming, Ou Zhiyu, Miao Yun. Research progress on application of shear wave elastography in kidney transplantation[J]. ORGAN TRANSPLANTATION, 2022, 13(2): 266-270. doi: 10.3969/j.issn.1674-7445.2022.02.017

剪切波弹性成像在肾移植中的应用进展

doi: 10.3969/j.issn.1674-7445.2022.02.017
基金项目: 

国家自然科学基金 82070770

广东省自然科学基金 2020A1515010674

广州市科技计划项目 201803010109

南方医院院长基金 2018B009

南方医院院长基金 2018C003

大学生创新创业训练计划项目 202012121046

大学生创新创业训练计划项目 X202012121239

详细信息
    作者简介:
    通讯作者:

    苗芸,女,1978年生,博士,主任医师,研究方向为肾移植,Email:miaoyunecho@126.com

  • 中图分类号: R617, R563

Research progress on application of shear wave elastography in kidney transplantation

More Information
  • 摘要: 移植肾功能障碍的早期检测对于免疫抑制的管理与移植肾的存活起着重要的作用,但由于移植肾功能障碍早期不会在临床表现以及生化指标上发生明显改变,因此其早期检测仍具有一定的挑战性。剪切波弹性成像技术作为近年来新兴的一种超声检查项目,已经成功应用于甲状腺、乳房、肝脏等器官的检查,因其具有实时、动态、准确与重复性较好等优点,在移植肾检查中也有良好的应用前景。本文对剪切波弹性成像技术的分类、原理、优势、影响因素及其在肾移植领域中的应用进行综述,旨在为临床医师在移植肾疾病的预防和监测方面做出正确的决策提供参考。

     

  • [1] QI R, YANG C, ZHU T. Advances of contrast-enhanced ultrasonography and elastography in kidney transplantation: from microscopic to microcosmic[J]. Ultrasound Med Biol, 2021, 47(2): 177-184. DOI: 10.1016/j.ultrasmedbio.2020.07.025.
    [2] EARLY H, AGUILERA J, CHEANG E, et al. Challenges and considerations when using shear wave elastography to evaluate the transplanted kidney, with pictorial review[J]. J Ultrasound Med, 2017, 36(9): 1771-1782. DOI: 10.1002/jum.14217.
    [3] 拉琼, 杨锦茹. 超声弹性成像应用于移植肾的研究进展[J]. 中国医药导报, 2019, 16(36): 40-45. https://www.cnki.com.cn/Article/CJFDTOTAL-YYCY201936009.htm

    LA Q, YANG JR. Research progress of the application of ultrasound elastography in transplanted kidney[J]. Chin Med Herald, 2019, 16(36): 40-45. https://www.cnki.com.cn/Article/CJFDTOTAL-YYCY201936009.htm
    [4] WANG Z, YANG H, SUO C, et al. Application of ultrasound elastography for chronic allograft dysfunction in kidney transplantation[J]. J Ultrasound Med, 2017, 36(9): 1759-1769. DOI: 10.1002/jum.14221.
    [5] BARR RG. Shear wave liver elastography[J]. Abdom Radiol (NY), 2018, 43(4): 800-807. DOI: 10.1007/s00261-017-1375-1.
    [6] 巩海燕, 周文斌, 邓晶, 等. 实时剪切波弹性成像和超声造影技术单独及联合诊断在乳腺癌中的应用价值[J]. 实用医学杂志, 2021, 37(13): 1742-1745. DOI: 10.3969/j.issn.1006-5725.2021.13.020.

    GONG HY, ZHOU WB, DENG J, et al. Diagnostic values of shear wave elastography and contrast-enhanced ultrasound techniques for breast cancer[J]. J Pract Med, 2021, 37(13): 1742-1745. DOI: 10.3969/j.issn.1006-5725.2021.13.020.
    [7] 何桥, 原文聪, 樊海宁, 等. 弹性成像联合血清学诊断慢性乙型肝炎肝纤维化的研究现状[J]. 临床肝胆病杂志, 2021, 37(12): 2914-2918. DOI: 10.3969/j.issn.1001-5256.2021.12.037.

    HE Q, YUAN WC, FAN HN, et al. Current status of research on elastography combined with serology in the diagnosis of chronic hepatitis B liver fibrosis[J]. J Clin Hepatol, 2021, 37(12): 2914-2918. DOI: 10.3969/j.issn.1001-5256.2021.12.037.
    [8] GRENIER N, GENNISSON JL, CORNELIS F, et al. Renal ultrasound elastography[J]. Diagn Interv Imaging, 2013, 94(5): 545-550. DOI: 10.1016/j.diii.2013.02.003.
    [9] DIETRICH CF, BAMBER J, BERZIGOTTI A, et al. EFSUMB guidelines and recommendations on the clinical use of liver ultrasound elastography, update 2017 (long version)[J]. Ultraschall Med, 2017, 38(4): e16-e47. DOI: 10.1055/s-0043-103952.
    [10] WANG B, GUO Q, WANG JY, et al. Ultrasound elastography for the evaluation of lymph nodes[J]. Front Oncol, 2021, 11: 714660. DOI: 10.3389/fonc.2021.714660.
    [11] CHIMORIYA R, PIYA MK, SIMMONS D, et al. The use of two-dimensional shear wave elastography in people with obesity for the assessment of liver fibrosis in non-alcoholic fatty liver disease[J]. J Clin Med, 2020, 10(1): 95. DOI: 10.3390/jcm10010095.
    [12] JEONG JY, CHO YS, SOHN JH. Role of two-dimensional shear wave elastography in chronic liver diseases: a narrative review[J]. World J Gastroenterol, 2018, 24(34): 3849-3860. DOI: 10.3748/wjg.v24.i34.3849.
    [13] OZTURK A, OLSON MC, SAMIR AE, et al. Liver fibrosis assessment: MR and US elastography[J]. Abdom Radiol (NY), 2021, DOI: 10.1007/s00261-021-03269-4 [Epub ahead of print].
    [14] MORGAN TA, JHA P, PODER L, et al. Advanced ultrasound applications in the assessment of renal transplants: contrast-enhanced ultrasound, elastography, and B-flow[J]. Abdom Radiol (NY), 2018, 43(10): 2604-2614. DOI: 10.1007/s00261-018-1585-1.
    [15] BOUCHET P, GENNISSON JL, PODDA A, et al. Artifacts and technical restrictions in 2D shear wave elastography[J]. Ultraschall Med, 2020, 41(3): 267-277. DOI: 10.1055/a-0805-1099.
    [16] 秦芩, 王丹丹, 党文珠, 等. 实时剪切波弹性成像技术在肾脏疾病中的应用进展[J]. 临床肾脏病杂志, 2020, 20(10): 846-849. DOI: 10.3969/j.issn.1671-2390.2020.10.016.

    QIN Q, WANG DD, DANG WZ, et al. Research progress on application of real-time shear wave elastography in kidney disease[J]. J Clin Nephrol, 2020, 20(10): 846-849. DOI: 10.3969/j.issn.1671-2390.2020.10.016.
    [17] HE WY, JIN YJ, WANG WP, et al. Tissue elasticity quantification by acoustic radiation force impulse for the assessment of renal allograft function[J]. Ultrasound Med Biol, 2014, 40(2): 322-329. DOI: 10.1016/j.ultrasmedbio.2013.10.003.
    [18] LEONG SS, WONG JHD, MD SHAH MN, et al. Stiffness and anisotropy effect on shear wave elastography: a phantom and in vivo renal study[J]. Ultrasound Med Biol, 2020, 46(1): 34-45. DOI: 10.1016/j.ultrasmedbio.2019.08.011.
    [19] JÄRV L, KULL I, RⅡSPERE Z, et al. Ultrasound elastography correlations between anthropometrical parameters in kidney transplant recipients[J]. J Investig Med, 2019, 67(8): 1137-1141. DOI: 10.1136/jim-2018-000970.
    [20] 李健明, 胡向东, 张岩峰, 等. 剪切波弹性成像的影响因素分析[J/CD]. 中华医学超声杂志(电子版), 2019, 16(8): 565-567. DOI: 10.3877/cma.j.issn.1672-6448.2019.08.002.

    LI JM, HU XD, ZHANG YF, et al. Analysis of influencing factors of shear wave elastography[J/CD]. Chin J Med Ultrasound (Electr Edit), 2019, 16(8): 565-567. DOI: 10.3877/cma.j.issn.1672-6448.2019.08.002.
    [21] SINGH H, PANTA OB, KHANAL U, et al. Renal cortical elastography: normal values and variations[J]. J Med Ultrasound, 2017, 25(4): 215-220. DOI: 10.1016/j.jmu.2017.04.003.
    [22] BOLBOACĂ SD, ELEC FI, ELEC AD, et al. Shear-wave elastography variability analysis and relation with kidney allograft dysfunction: a single-center study[J]. Diagnostics (Basel), 2020, 10(1): 41. DOI: 10.3390/diagnostics10010041.
    [23] KENNEDY P, BANE O, HECTORS SJ, et al. Magnetic resonance elastography vs. point shear wave ultrasound elastography for the assessment of renal allograft dysfunction[J]. Eur J Radiol, 2020, 126: 108949. DOI: 10.1016/j.ejrad.2020.108949.
    [24] NAKAO T, USHIGOME H, NAKAMURA T, et al. Evaluation of renal allograft fibrosis by transient elastography (Fibro Scan)[J]. Transplant Proc, 2015, 47(3): 640-643. DOI: 10.1016/j.transproceed.2014.12.034.
    [25] MA MK, LAW HK, TSE KS, et al. Non-invasive assessment of kidney allograft fibrosis with shear wave elastography: a radiological-pathological correlation analysis[J]. Int J Urol, 2018, 25(5): 450-455. DOI: 10.1111/iju.13536.
    [26] EARLY HM, CHEANG EC, AGUILERA JM, et al. Utility of shear wave elastography for assessing allograft fibrosis in renal transplant recipients: a pilot study[J]. J Ultrasound Med, 2018, 37(6): 1455-1465. DOI: 10.1002/jum.14487.
    [27] YANG JR, LA Q, DING XM, et al. Using real-time sound touch elastography to monitor changes in transplant kidney elasticity[J]. Clin Radiol, 2020, 75(12): 963. e1-963. e6. DOI: 10.1016/j.crad.2020.08.013.
    [28] GOYAL A, HEMACHANDRAN N, KUMAR A, et al. Evaluation of the graft kidney in the early postoperative period: performance of contrast-enhanced ultrasound and additional ultrasound parameters[J]. J Ultrasound Med, 2021, 40(9): 1771-1783. DOI: 10.1002/jum.15557.
    [29] CHEN S, LI J, ZENG B, et al. The stiffness of transplanted kidneys changes with time after renal transplantation[J]. Acta Radiol, 2021, DOI: 10.1177/02841851211030770 [Epub ahead of print].
    [30] CHEN Y, WANG B, XIAO L, et al. Changes in muscle mass in patients with renal transplants based on ultrasound: a prospective study[J]. J Ultrasound Med, 2021, 40(8): 1637-1648. DOI: 10.1002/jum.15552.
  • 加载中
图(1)
计量
  • 文章访问数:  315
  • HTML全文浏览量:  86
  • PDF下载量:  77
  • 被引次数: 0
出版历程
  • 收稿日期:  2021-11-06
  • 网络出版日期:  2022-03-18
  • 刊出日期:  2022-03-15

目录

    /

    返回文章
    返回